{"id":5073,"date":"2020-12-15T18:17:41","date_gmt":"2020-12-15T16:17:41","guid":{"rendered":"https:\/\/www.valves-community.com\/?p=5073"},"modified":"2024-01-10T16:41:45","modified_gmt":"2024-01-10T14:41:45","slug":"oxygen-air-separation-glass-wool","status":"publish","type":"post","link":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/","title":{"rendered":"Out of thin air &#8211; Oxygen from air separation for glass wool"},"content":{"rendered":"<p><strong>At temperatures over 1000 \u00b0C and with oxygen support from air separation, glass candy floss is produced, which has excellent insulating properties.<\/strong><\/p>\n<p>The new air separation plant in Speyer extracts 260 tonnes of nitrogen and 130 tonnes of oxygen from the ambient air every day, plus 10 tonnes of the noble gas argon. The gases obtained are used in many production processes, such as in the manufacture of glass wool, which is used to insulate buildings. Important technical cogs in the gearbox of the plant are the Top Entry Valves from HEROSE.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-5086 size-full\" title=\"Air separation plant in Speyer\" src=\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/air-separation-plant-speyer.jpg\" alt=\"Air separation plant in Speyer\" width=\"1024\" height=\"680\" srcset=\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/air-separation-plant-speyer.jpg 1024w, https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/air-separation-plant-speyer-300x199.jpg 300w, https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/air-separation-plant-speyer-768x510.jpg 768w, https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/air-separation-plant-speyer-450x300.jpg 450w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<h2>New air separation plant in Speyer<\/h2>\n<p>When the foundation stone for the air separation plant in Speyer was laid at the end of June 2019, this stone contained a time capsule containing a current daily newspaper. The news in it: tax evasion, mafia crimes and a heat record by the high, Ulla. How the world can change during the 16 months of construction:<br \/>\nToday, the pandemic determines the news situation almost daily and the ceremonial inauguration, the plant completed in October 2020 had to be cancelled \u2013 safety first. But the plant is firing up good news, for example because combustion processes run more efficiently and in a more environmentally friendly way with the help of the recovered gases.<\/p>\n<p>&nbsp;<\/p>\n<h3>Fewer transports \u2013 greater security of supply<\/h3>\n<p>Industrial gas specialist, Messer, has invested \u20ac 32 million in its third air separation plant in Germany. The plant was built directly on the premises of the customer, Saint-Gobain Isover, in the industrial<br \/>\nestate south of Speyer. This is indeed a win-win situation: Up to now, the Isover plant has been supplied with the necessary oxygen from Siegen by scores of tankers every day. This amounts to several hundred thousand truck kilometres per year \u2013 a considerable expense and a burden on the environment. Today, Isover is supplied with gaseous oxygen through a 250 metres long underground pipeline. A large proportion of the oxygen produced daily in Speyer is taken from Isover. In addition, other customers in south-western Germany are reached via shorter supply routes.<\/p>\n<p>&nbsp;<\/p>\n<h3>Air separation<\/h3>\n<p>Air is a gas mixture consisting mainly of nitrogen (78 %), oxygen (21 %) and the noble gas argon (0.9 %). Due to their natural occurrence in the atmosphere, these gases are available in almost unlimited quantities. In the separation plant, the individual air components are separated from each other by gas distillation to obtain nitrogen, oxygen and argon in high-purity concentrations \u2013 liquid and gaseous. In many production processes, air gases are as important as water and electricity. Nitrogen is often used as a safety gas for explosion protection in chemical production and pharmaceuticals. Oxygen is used to make combustion processes more efficient and environmentally friendly because, compared to air combustion, no nitrogen oxides are emitted, and fuel is saved. The noble gas, argon, serves as a shielding gas during welding, plays a central role in stainless steel production and also in semiconductor manufacture.<\/p>\n<blockquote><p><em>&#8220;With direct supply, we minimise the logistics costs of transporting gases by road.&#8221;<\/em><\/p><\/blockquote>\n<p style=\"text-align: right;\"><span style=\"color: #339966;\">Stefan Messer, Owner and CEO of the Messer Group<\/span><\/p>\n<p>&nbsp;<\/p>\n<h2>How air separation works<\/h2>\n<div class=\"su-row\">\n<div class=\"su-column su-column-size-2-3\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-5024 size-full\" title=\"How air separation works\" src=\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/grafik-funktionsweise-luftzerlegung.jpg\" alt=\"How air separation works\" width=\"678\" height=\"657\" srcset=\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/grafik-funktionsweise-luftzerlegung.jpg 678w, https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/grafik-funktionsweise-luftzerlegung-300x291.jpg 300w\" sizes=\"auto, (max-width: 678px) 100vw, 678px\" \/><\/p>\n<\/div><\/div>\n<div class=\"su-column su-column-size-1-3\"><div class=\"su-column-inner su-u-clearfix su-u-trim\">\n<div class=\"su-accordion su-u-trim\"><div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-plus accText su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span><strong>1 Compress air<\/strong><\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">Ambient air is sucked in, filtered and<br \/>\ncompressed to 6 bar by a compressor.<\/div><\/div> <div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-plus accText su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span><strong>2 Pre-cool air<\/strong><\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">Initially, the compressed air is pre-cooled with the help of water.<\/div><\/div> <div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-plus accText su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span><strong>3 Clean air<\/strong><\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">Subsequently, the air is freed from disturbing components such as water vapour and carbon dioxide.<\/div><\/div> <div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-plus accText su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span><strong>4 Cool air<\/strong><\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">The cleaned air is cooled down to about -175 \u00b0C in the main heat exchanger. Now the air can be separated in the real air separator, the separation column.<\/div><\/div> <div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-plus accText su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span><strong>5 Separate air<\/strong><\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">During the separation process, the different boiling points of the air components are used: oxygen liquefies at -183 \u00b0C and nitrogen at -196 \u00b0C. Through the exchange between rising vapour and descending liquid, continuous evaporation and condensation at the top of the low-pressure column produces pure nitrogen and pure oxygen at the bottom. The argon is extrected by further separation columns and process steps.<\/div><\/div> <div class=\"su-spoiler su-spoiler-style-default su-spoiler-icon-plus accText su-spoiler-closed\" data-scroll-offset=\"0\" data-anchor-in-url=\"no\"><div class=\"su-spoiler-title\" tabindex=\"0\" role=\"button\"><span class=\"su-spoiler-icon\"><\/span><strong>6 Removal and storage<\/strong><\/div><div class=\"su-spoiler-content su-u-clearfix su-u-trim\">Gaseous oxygen and nitrogen are fed into a pipeline network and fed directly to the consumer. Oxygen, nitrogen and argon in liquid form are stored temporarily in storage tanks and transported via trailer to the consumer.<\/div><\/div><\/div>\n<\/div><\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h2>Gas meets glass<\/h2>\n<p>The production of glass wool requires energy to melt the raw material in the furnace at 1400 \u00b0C. The main raw materials used are waste glass (up to 80 %), sand, limestone and soda ash. Saint-Gobain Isover has been using oxygen melting technology since mid-2019 \u2013 previously, normal outside air was used. Pure oxygen makes the combustion process more efficient, more economical and cleaner: natural gas savings of 10 to 20 %, less nitrogen oxide and CO2 emissions and less particulate matter. The working environment is also improved due to lower noise and heat pollution. Overall, oxygen technology allows faster and more consistent melting and better glass quality.<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-5040 size-full\" title=\" Roof extension with glass wool\" src=\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/isover.jpg\" alt=\" Roof extension with glass wool\" width=\"1024\" height=\"454\" srcset=\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/isover.jpg 1024w, https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/isover-300x133.jpg 300w, https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/isover-768x341.jpg 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h3>The production of glass wool is practically a waste-free production<\/h3>\n<p>After passing through the furnace, the glassy melt is defibrated: a thin glass jet hits rapidly rotating defibration rings and is ejected from the ring through thousands of tiny holes. The resulting threads are defibrated by gas burners to produce even finer wool threads. The fibres are sprayed with small quantities of a binder dissolved in water. The binder is cured in a tunnel kiln at approx. 200 \u00b0C. Later, the glass wool is cut to the desired size and shape \u2013 in rolls, mats or sheets. Residues and sections of mineral wool are returned to the production process.<\/p>\n<blockquote><p><em>&#8220;The defibration process of the molten glass works in a similar way to the production of candyfloss: The finest threads are produced &#8211; the basis of glass wool.&#8221;<\/em><\/p><\/blockquote>\n<p style=\"text-align: right;\"><span style=\"color: #339966;\">Michel Wenger, Head of Corporate Communications Saint-Gobain Isover<\/span><\/p>\n<p>&nbsp;<\/p>\n<h2>Maximum efficiency for cryogenic applications<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-5047 size-full\" title=\"Air separation with Top Entry Valve Type 01420\" src=\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/type-01420.jpg\" alt=\"Air separation with Top Entry Valve Type 01420\" width=\"186\" height=\"600\" srcset=\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/type-01420.jpg 186w, https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/type-01420-93x300.jpg 93w\" sizes=\"auto, (max-width: 186px) 100vw, 186px\" \/>The air separation plant in Speyer uses, among others, the Top Entry Valve 01420 from HEROSE. Since the piping is inside the cold box, i.e. inside the insulated jacket, only the handwheels or actuators are outside. The valve internals must therefore be removable from the outside even when installed. This is where the Top Entry Valve 01420 shows its strengths: It enables maintenance work to be carried out on the cone or upper part without having to damage the insulation because the topwork screws are outside the insulation. This construction method offers great potential for saving material, costs and time. Further HEROSE cryogenic globe valves are used for the control of material flows in tank storage. In addition, HEROSE safety valves are installed in the plant for protection against overpressure.<\/p>\n<div class=\"su-service\"><div class=\"su-service-title\" style=\"padding-left:46px;min-height:32px;line-height:32px\"><i class=\"sui sui-square\" style=\"font-size:32px;color:#339933\"><\/i> More information to Top Entry Valve Type 01420:<\/div><div class=\"su-service-content su-u-clearfix su-u-trim\" style=\"padding-left:46px\">\n<a href=\"https:\/\/www.herose.com\/eng\/products\/cryogenic-services\/01420.php\" target=\"_blank\" rel=\"noopener\">Top Entry Valve \u2013 Type 01420<\/a><br \/>\n<\/div><\/div>\n<p>Photos: Messer Industriegase GmbH, Saint-Gobain Isover G+H AG<\/p>\n<p>&nbsp;<\/p>\n<h3>Did you like this article?<\/h3>\n<p>Please get further information and background reports about industrial valves and applications via the free HEROSE newsletter.<\/p>\n<a href=\"https:\/\/www.herose.com\/eng\/\" class=\"su-button su-button-style-flat\" style=\"color:#FFFFFF;background-color:#339933;border-color:#297b29;border-radius:5px\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"color:#FFFFFF;padding:0px 16px;font-size:13px;line-height:26px;border-color:#71b871;border-radius:5px;text-shadow:none\"> Subscribe here<\/span><\/a>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>At temperatures over 1000 \u00b0C and with oxygen support from air separation, glass candy floss is produced, which has excellent insulating properties. The new air separation plant in Speyer extracts 260 tonnes of nitrogen and 130 tonnes of oxygen from [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":5084,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[402],"tags":[592,534,533,518,517],"class_list":["post-5073","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cryogenic-air-gases","tag-air-separation","tag-cryogenic-service","tag-cryogenic-valves","tag-liquid-nitrogen","tag-liquid-oxygen"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Air separation supplies oxygen for the production of glass wool<\/title>\n<meta name=\"description\" content=\"With the support of oxygen from air separation, glass wool with excellent insulation properties is created.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Air separation supplies oxygen for the production of glass wool\" \/>\n<meta property=\"og:description\" content=\"With the support of oxygen from air separation, glass wool with excellent insulation properties is created.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/\" \/>\n<meta property=\"og:site_name\" content=\"Valves Community - powered by HEROSE GROUP\" \/>\n<meta property=\"article:published_time\" content=\"2020-12-15T16:17:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-01-10T14:41:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/oxygen-air-separation-glass-wool-production.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1400\" \/>\n\t<meta property=\"og:image:height\" content=\"560\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"HEROSE\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"HEROSE\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/\"},\"author\":{\"name\":\"HEROSE\",\"@id\":\"https:\/\/www.valves-community.com\/en\/#\/schema\/person\/635fa116593978a0d803e860ee55a641\"},\"headline\":\"Out of thin air &#8211; Oxygen from air separation for glass wool\",\"datePublished\":\"2020-12-15T16:17:41+00:00\",\"dateModified\":\"2024-01-10T14:41:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/\"},\"wordCount\":1284,\"publisher\":{\"@id\":\"https:\/\/www.valves-community.com\/en\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/oxygen-air-separation-glass-wool-production.jpg\",\"keywords\":[\"air separation\",\"Cryogenic service\",\"Cryogenic valves\",\"Liquid nitrogen\",\"Liquid oxygen\"],\"articleSection\":[\"Cryo air gases\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/\",\"url\":\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/\",\"name\":\"Air separation supplies oxygen for the production of glass wool\",\"isPartOf\":{\"@id\":\"https:\/\/www.valves-community.com\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/oxygen-air-separation-glass-wool-production.jpg\",\"datePublished\":\"2020-12-15T16:17:41+00:00\",\"dateModified\":\"2024-01-10T14:41:45+00:00\",\"description\":\"With the support of oxygen from air separation, glass wool with excellent insulation properties is created.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#primaryimage\",\"url\":\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/oxygen-air-separation-glass-wool-production.jpg\",\"contentUrl\":\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/oxygen-air-separation-glass-wool-production.jpg\",\"width\":1400,\"height\":560,\"caption\":\"Oxygen from air separation for glass wool production\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.valves-community.com\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Out of thin air &#8211; Oxygen from air separation for glass wool\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.valves-community.com\/en\/#website\",\"url\":\"https:\/\/www.valves-community.com\/en\/\",\"name\":\"Valves Community - powered by HEROSE GROUP\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.valves-community.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.valves-community.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.valves-community.com\/en\/#organization\",\"name\":\"Valves Community - powered by HEROSE GROUP\",\"url\":\"https:\/\/www.valves-community.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.valves-community.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2022\/11\/vc-logo-22.png\",\"contentUrl\":\"https:\/\/www.valves-community.com\/wp-content\/uploads\/2022\/11\/vc-logo-22.png\",\"width\":450,\"height\":67,\"caption\":\"Valves Community - powered by HEROSE GROUP\"},\"image\":{\"@id\":\"https:\/\/www.valves-community.com\/en\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.valves-community.com\/en\/#\/schema\/person\/635fa116593978a0d803e860ee55a641\",\"name\":\"HEROSE\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Air separation supplies oxygen for the production of glass wool","description":"With the support of oxygen from air separation, glass wool with excellent insulation properties is created.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/","og_locale":"en_US","og_type":"article","og_title":"Air separation supplies oxygen for the production of glass wool","og_description":"With the support of oxygen from air separation, glass wool with excellent insulation properties is created.","og_url":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/","og_site_name":"Valves Community - powered by HEROSE GROUP","article_published_time":"2020-12-15T16:17:41+00:00","article_modified_time":"2024-01-10T14:41:45+00:00","og_image":[{"width":1400,"height":560,"url":"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/oxygen-air-separation-glass-wool-production.jpg","type":"image\/jpeg"}],"author":"HEROSE","twitter_misc":{"Written by":"HEROSE","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#article","isPartOf":{"@id":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/"},"author":{"name":"HEROSE","@id":"https:\/\/www.valves-community.com\/en\/#\/schema\/person\/635fa116593978a0d803e860ee55a641"},"headline":"Out of thin air &#8211; Oxygen from air separation for glass wool","datePublished":"2020-12-15T16:17:41+00:00","dateModified":"2024-01-10T14:41:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/"},"wordCount":1284,"publisher":{"@id":"https:\/\/www.valves-community.com\/en\/#organization"},"image":{"@id":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#primaryimage"},"thumbnailUrl":"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/oxygen-air-separation-glass-wool-production.jpg","keywords":["air separation","Cryogenic service","Cryogenic valves","Liquid nitrogen","Liquid oxygen"],"articleSection":["Cryo air gases"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/","url":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/","name":"Air separation supplies oxygen for the production of glass wool","isPartOf":{"@id":"https:\/\/www.valves-community.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#primaryimage"},"image":{"@id":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#primaryimage"},"thumbnailUrl":"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/oxygen-air-separation-glass-wool-production.jpg","datePublished":"2020-12-15T16:17:41+00:00","dateModified":"2024-01-10T14:41:45+00:00","description":"With the support of oxygen from air separation, glass wool with excellent insulation properties is created.","breadcrumb":{"@id":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#primaryimage","url":"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/oxygen-air-separation-glass-wool-production.jpg","contentUrl":"https:\/\/www.valves-community.com\/wp-content\/uploads\/2020\/12\/oxygen-air-separation-glass-wool-production.jpg","width":1400,"height":560,"caption":"Oxygen from air separation for glass wool production"},{"@type":"BreadcrumbList","@id":"https:\/\/www.valves-community.com\/en\/cryogenic-air-gases\/oxygen-air-separation-glass-wool\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.valves-community.com\/en\/"},{"@type":"ListItem","position":2,"name":"Out of thin air &#8211; Oxygen from air separation for glass wool"}]},{"@type":"WebSite","@id":"https:\/\/www.valves-community.com\/en\/#website","url":"https:\/\/www.valves-community.com\/en\/","name":"Valves Community - powered by HEROSE GROUP","description":"","publisher":{"@id":"https:\/\/www.valves-community.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.valves-community.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.valves-community.com\/en\/#organization","name":"Valves Community - powered by HEROSE GROUP","url":"https:\/\/www.valves-community.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.valves-community.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.valves-community.com\/wp-content\/uploads\/2022\/11\/vc-logo-22.png","contentUrl":"https:\/\/www.valves-community.com\/wp-content\/uploads\/2022\/11\/vc-logo-22.png","width":450,"height":67,"caption":"Valves Community - powered by HEROSE GROUP"},"image":{"@id":"https:\/\/www.valves-community.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.valves-community.com\/en\/#\/schema\/person\/635fa116593978a0d803e860ee55a641","name":"HEROSE"}]}},"_links":{"self":[{"href":"https:\/\/www.valves-community.com\/en\/wp-json\/wp\/v2\/posts\/5073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.valves-community.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.valves-community.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.valves-community.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.valves-community.com\/en\/wp-json\/wp\/v2\/comments?post=5073"}],"version-history":[{"count":19,"href":"https:\/\/www.valves-community.com\/en\/wp-json\/wp\/v2\/posts\/5073\/revisions"}],"predecessor-version":[{"id":6117,"href":"https:\/\/www.valves-community.com\/en\/wp-json\/wp\/v2\/posts\/5073\/revisions\/6117"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.valves-community.com\/en\/wp-json\/wp\/v2\/media\/5084"}],"wp:attachment":[{"href":"https:\/\/www.valves-community.com\/en\/wp-json\/wp\/v2\/media?parent=5073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.valves-community.com\/en\/wp-json\/wp\/v2\/categories?post=5073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.valves-community.com\/en\/wp-json\/wp\/v2\/tags?post=5073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}